268 x 165 mm minimum pitch.
Plain roof tiles minimum pitch.
Interlocking clay plain tiles 15 degrees.
Florida building code fbc specifies that clay and concrete tile be installed to the standards in the florida roofing and sheet metal association s frsa concrete and clay roof tile installation manual.
60 tiles m at 100mm gauge roof 53 tiles m at 115mm gauge vertical weight of tiling.
Below 90 at 90 tile thickness.
165 mm covering capacity net 60 tiles m.
Click for original site.
Natural slate 25 degrees.
The international residential code irc specifies a minimum 4 12 pitch 4 inches of vertical rise for every 12 inches of horizontal run for a clay or concrete tile roof except that a pitch as low as 2 1 2 12 is allowed when two layers of underlayment are applied.
With the introduction of machine made clay tiles this has now dropped slightly to 30 similar to the marley hawkins single camber tile.
13 mm hanging length.
73 8kg m 0 72 kn m at 100mm gauge roof.
Clay pantiles 30 degrees.
100 mm 115 mm.
Below 90 at 90 maximum headlap.
88 mm minimum gauge.
267mm x 165mm.
Traditionally a minimum roof pitch of 20 was recommended in bs 5534 but modern tiles and slates have now been designed for applications as low as 15.
100mm roof 115mm vertical cover width.
As a general rule tiles and slates will perform down to the pitches outlined below.
Previously it was accepted that 35 was the lowest recommended pitch for both concrete and clay variants of the tile.
For example a roof that rises 3 inches for every 12 inches has a pitch of 3 12.
Sunday july 1 2018.
Plain tiles 35 degrees.
It has long been enshrined in our british standards for roofing that the minimum roof pitch for plain tiles is 35 degrees or 40 degrees for handmade clay tiles that do not fall into the geometric tolerances set manufacturing standards.
To calculate roof pitch take the lowest point of the roof and measure the amount of rise for every 12 inches of horizontal movement toward the highest point.
88 mm maximum gauge.
On some developments design limitations can arise on comparatively small areas of the roof which restrict the available roof pitch to below 35 which is the minimum pitch recommended for all plain tiles in bs en 5534.
Guidelines for roof sections falling below a 35 pitch.
It is this long experience in use that tells us what the minimum roof pitch should be and how to achieve the many intricate and interesting roof designs that suit plain tiles.
Clay single camber plain tiles can pitch down to 30 manufacturer dependant although the vast majority available have a limit of 35.
90 subject to fixing specification.
Plain tile technical data size.
Interlocking concrete and clay tiles 22 5 degrees.
65 mm 35 mm.
It is uncommon to find a roof below 15 but for those very low pitch applications there are interlocking clay pantiles available suitable for use down to 12 5.